2P2W PROP PILOT OP. POPPET NC
FAP121CV
Udsolgt
Information
| Afdeling | Hydraulic Cartridge Systems Division |
| Aktiveringstype | Electrical |
| Body materiale | N/A |
| Bypassfunktionalitet | N/A |
| Driftstemperatur | -26 to +204 �C |
| Filters effektivitetsklassificering | ISO 4406 18/16/13, SAE Class 4 |
| Flowhastighed | 81.5 L/min |
| Flowretning | Side to Nose (2 - 1) |
| For væsketype | Mineral-based or synthetic hydraulic fluids |
| Form størrelse | C12-2F |
| Frekvens | 100-400 Hz |
| Funktion | Proportional Flow Control/Regulator |
| Hysterese | < 15% |
| Installationsmoment | 55 lb-ft |
| Konfiguration | Normally Closed |
| Konfiguration | Normally Closed |
| Lækagehastighed | 5 @ 3000 PSI (210 BAR) drops/min |
| Maks. driftstemperatur | +204 �C |
| Maks. driftstryk | 210 bar |
| Maks. flowhastighed | 21.5 Gal/min |
| Maks. flowhastighed | 21.5 GAL/MIN, 81.5 L/MIN |
| Maksimal kinematisk viskositet | 45-2000 SSU (6 to 420 cSt) |
| Maksimalt indløbstryktrin | 3000 psi |
| Mindste driftstemperatur | -15 �F |
| Mindste trykdifferens | 300 psi |
| Pakningsmateriale | Fluorocarbon |
| Pakningsmateriale | Fluorocarbon |
| partId (right) | 2395259 |
| Spolemøtriks tilspændingsmoment | 1.4 Nm |
| Spoletype | 5/8" Super Coil Low Watt (CAS) |
| Strømforbrug | 18 W |
| Variation af lukkepunkt | N/A |
| Variation af åbningspunkt | 20-25% of Input Signal |
| Ventilmateriale | All parts steel. All operating parts hardened steel |
| Vægt | 0.65 lb |